MAXI STANDARD – MS is designed for higher hot water needs. The water in the tank is heated by integrated electric panels (2×7.5 kW) or by the OSO TURBO system. The electrical panels are switched from the standard voltage of 3×230 to possibly 400V, are thermostatically controlled between 50 – 75°C, and the power cables are connected directly in the electrical panel. The supply cables are separated to prevent the power of the electrical centres from being connected at the same time, thereby reducing the power link in the event of lower hot water demand. Contactors are unnecessary and the power cable is connected directly at the centre. The safety valve is included and sized in accordance with. EN 1490.
The MAXI is constructed from EVERLASTTM stainless steel combined with ULTRAWELDTM technology. The MAXI is available up to 15,000 L with a pressure class of 10 bar and can be customised if required.
Model | Maxi Standard | Maxi Standard | Maxi Standard | Maxi Standard | Maxi Standard | Maxi Standard | Maxi Standard |
---|---|---|---|---|---|---|---|
Product Code | MS 300 | MS 400 | MS 600 | MS 1000 | MS 2000 | MS 3000 | MS 5000 |
Name | MS 300 – 2×7.5kW/3x230V | MS 400 – 2×7.5kW/3x230V | MS 600 – 2×7.5kW/3x230V | MS 1 000 – 2×7.5kW/3x230V | MS 2 000 – 30kW/3x230V280 | MS 3 000 – 30kW/3x230V | MS 5 000 – 2x30kW/3×230 |
Diameter x Height mm | 595×1682 | 595×2172 | 800×2030 | 1000×2100 | 1290×2450 | 1490×2700 | 1690×3190 |
Weight kg | 59 | 79 | 105 | – | – | – | – |
Coil area m2. | – | – | – | – | – | – | – |
Nominal capacity l. | 280 | 372 | 570 | – | – | – | – |
Standing losses W | 83 | 90 | – | – | – | – | – |
Thermostat setting °C | 75 | 75 | 75 | 75 | 75 | 75 | 75 |
Energy Class | C | C | – | – | – | – | – |